Skip to content

Choose a chromatin pipeline

The assay determines the pipeline inputs. Paired FASTQ files alone cannot tell a workflow whether they describe open chromatin, immunoprecipitated DNA, or antibody-directed cleavage. The sample table must preserve that experimental meaning.

Pipeline Selected release Inputs and role
nf-core/atacseq 2.1.2 ATAC-seq reads produce alignments, QC reports, peaks, consensus counts, and tracks.
nf-core/chipseq 2.1.0 ChIP-seq samples and appropriate controls support peak and enrichment analysis.
nf-core/cutandrun 3.2.2 CUT&RUN or CUT&Tag samples support antibody controls, spike-ins, and assay-specific peak analysis.

The ATAC-seq workflow supplies this section’s primary execution. The other two pipelines are reference explanations in this release.

Preserve sample identity through the workflow

Section titled “Preserve sample identity through the workflow”

The ATAC samplesheet uses a condition name and a replicate number. Here, resting replicate 1 and stimulated replicate 1 both belong to donor 1001. The separate metadata table preserves that donor relationship for downstream analysis.

Repeated sequencing of one sample belongs to that sample’s existing biological replicate. Pooling all donors into one alignment can support a display track, but a pooled file cannot replace the independent donor columns in a statistical model. This section keeps the eight sample profiles separate.

A BAM file contains alignments. A peak file contains called intervals. A count matrix contains measurements over a shared region definition. A bigWig contains signal values with a particular scale and denominator.

Those files are not interchangeable. Peak scores and normalized bigWig values must not become raw counts in DESeq2. A peak list also cannot supply mitochondrial fractions or the original library complexity. Those quantities need the appropriate reads, alignments, or primary reports.

The ATAC pipeline lesson connects the actual configuration to its output files. The count lesson then checks the values that enter the paired model.

A pipeline release fixes its workflow source but can still refer to external configuration, plugins, reference files, and container tags. The execution record must identify those dependencies as well as the pipeline release.

The selected runtime uses Nextflow 26.04.0 with its legacy parser because ATAC release 2.1.2 contains configuration functions that the strict parser rejects. This is the documented compatibility setting in the Nextflow migration guide. It does not change the scientific comparison.

A successful test profile checks workflow compatibility on its test inputs. It does not validate the eight donor samples. The separate execution record identifies the cohort run and its acceptance evidence.

An input DNA control describes background in a ChIP experiment. An IgG control describes signal recovered without the intended antibody specificity. A spike-in provides a reference under assumptions about its amount, recovery, and point of addition.

These controls answer different questions. Selecting a control column in a samplesheet cannot repair an experiment that omitted the needed control. Read the controls lesson before adapting an ATAC configuration for an antibody assay.

The nf-core/chipseq 2.1.0 usage guide defines replicate and control assignments for ChIP-seq. Its samplesheet rules differ from the ATAC-seq workflow.

The nf-core/cutandrun 3.2.2 usage guide describes controls, spike-ins, normalization, and supported assays. These settings help match a pipeline to the experimental design.