Experimental Design
Why design comes first
Section titled “Why design comes first”An affinity assay runs in plates, and every plate is a small batch with its own reagents, incubations, washes and reader run. The analysis can remove a difference between plates only when it can tell that difference apart from biology, and the layout decides whether it can. A curve that misses the range of your samples, a matrix that differs between groups, or a kit lot that changes halfway through cannot be fixed by any model afterward.
Plate layout and randomization
Section titled “Plate layout and randomization”Spread every group across every plate. If all cases run on plate 1 and all controls on plate 2, the plate effect and the group effect are the same number. Olink’s normalization white paper spells out the consequence. Intensity normalization assumes that an assay has the same median on every plate, which holds only when samples are randomized, and with poor randomization it can remove real biological variation. For studies that cannot be randomized, the paper recommends reference samples on every plate.
Randomize on the variables that matter for your question, such as group, treatment, time point and site. Olink’s plate randomization vignette adds a rule for longitudinal studies. Keep all samples from one subject on one plate, then spread the subjects, so changes within a subject carry no plate difference. The MGH cohort used later in this section was randomized by group, and Filbin et al. 2021 describe allocating its samples randomly onto plates based on disease outcome grouping.
Standards and their dilution series
Section titled “Standards and their dilution series”ELISA and Luminex need a calibration curve on every plate. ICH M10, the international guideline on bioanalytical method validation, asks for at least six concentration levels plus a blank, prepared in the same matrix as the study samples. The lowest and highest standards define the lower and upper limits of quantification, LLOQ and ULOQ. The R&D Systems DuoSet protocol recommends seven points of twofold dilution.
M10 covers drug assays and leaves biomarkers out of its scope, but the FDA’s guidance on biomarker assays names it as the starting point for validating them, especially ligand binding assays.
The range of the curve is the range of your results. A signal below the lowest standard gives a bound, not a concentration, and one above the highest standard needs dilution and a rerun. Choose the standards and the sample dilution from published values or a pilot plate, so that most samples land between LLOQ and ULOQ. Olink has no standard curve and rests its NPX values on controls instead.
Blanks and QC controls
Section titled “Blanks and QC controls”A blank, or zero standard, gives the background. The DuoSet protocol subtracts its average optical density from every reading, and M10 keeps the blank out of the curve fit.
QC samples are not standards. They have known concentrations, are prepared separately from the standard series, and test whether the run worked. M10 asks for low, medium and high QCs on every plate, placed before and after the study samples, and passes a run when the back calculated standards fall within 20% of nominal, or 25% at the LLOQ and ULOQ, and at least two thirds of the QCs fall within 20%.
Olink builds its controls into every well and every plate. The white paper lists two incubation controls, an extension control and a detection control spiked into each sample. Each plate adds an inter plate control and a negative control in triplicate, and Olink recommends a pooled plasma sample control in duplicate. A sample fails QC when its incubation control 2 or detection control sits more than 0.3 NPX from the plate median.
Technical replicates and CV targets
Section titled “Technical replicates and CV targets”Technical replicates are the same sample in two or more wells. Their coefficient of variation, the standard deviation divided by the mean, measures pipetting, washing and reading noise, and says nothing about biology. The DuoSet protocol runs every standard and sample in duplicate.
M10 sets the precision limit for QCs in ligand binding assays at a CV of 20% within and between runs, or 25% at the LLOQ and ULOQ, with a total error limit of 30%, or 40% at the limits. Precision is worse at the ends of the curve, where the signal barely moves with concentration. A replicate pair that disagrees near the LLOQ is common, while the same disagreement mid curve points to a pipetting or washing error. Olink measures precision with its pooled plasma control. None of these replicates replace biological ones, since five wells of one patient still measure one patient.
Bridging samples between plates or projects
Section titled “Bridging samples between plates or projects”Bridge samples are the same samples measured in two runs, and they are the direct way to put runs that were not randomized together on one scale. Olink’s bridging tutorial recommends bridging when batches ran at different times, when reagent lots or run conditions changed, and when intensity normalized data come from different populations. It advises against combining datasets that share no samples, and it lists how many bridges to run.
| Olink product | Bridge samples recommended |
|---|---|
| Target 96 | 8 to 16 |
| Explore 3072 | 16 to 24 |
| Explore HT | 16 to 32 |
| Explore 3072 to Explore HT | 40 to 64 |
OlinkAnalyze shifts one dataset by the median of the paired differences between bridge samples, assay by assay, as its package manual describes, and the Bridging page runs it. Set aside aliquots that span the cohort before the first project, so a later one can rerun them.
ELISA and Luminex need the same habit. Run one control from a large pool of single use aliquots on every plate of every batch.
Sample matrix
Section titled “Sample matrix”Serum and plasma are different samples. Clotting activates platelets, which release their contents into serum, and Webb et al. 1998 found serum VEGF higher than plasma VEGF in children and adults, rising with clotting time. They concluded that plasma is the right medium for circulating VEGF.
Choose one matrix and one tube type for the whole study, and record the tube. The white paper defines matrix effects as changes in the readout caused by any sample component other than the analyte, and the anticoagulant is one such component. M10 asks for standards and QCs in the same matrix as the samples.
Preanalytical variables
Section titled “Preanalytical variables”Proteins keep changing after the blood is drawn. Shen et al. 2017 held EDTA blood for up to 36 hours before centrifugation and measured the plasma with Olink PEA. Of 139 detectable proteins, 16 rose significantly at 4 °C and 40 at 22 °C, some after one hour at room temperature. Up to eight freeze and thaw cycles changed no protein significantly, though that covers one panel, not every protein. Their advice is a short delay at a refrigerated temperature.
Hemolysis spills red cell contents into the sample, and M10 asks validation to test hemolyzed and lipemic samples. Record the tube, the time to centrifugation, the storage temperature, the number of thaws and any hemolysis flag for every sample. None of these can be reconstructed later.
Dilution and the hook effect
Section titled “Dilution and the hook effect”Many ligand binding assays have a narrow range, so samples often need dilution. A further diluted sample should give the same concentration once multiplied back, and M10 asks for agreement within 20%.
The hook effect is the reason to check. When a protein far outnumbers the antibodies, the capture and detection antibodies each bind free protein, sandwiches fail to form, and the signal falls as concentration rises. Tighe et al. 2015 note that bead assays run in one step are prone to it. An extreme sample can then read as a moderate one. If the corrected concentration rises as you dilute, the undiluted well was hooked, and M10 runs this test on a sample spiked above the ULOQ.
In a multiplex panel one dilution has to serve every analyte, and Tighe et al. 2015 call a single dilution that suits a whole panel often unfeasible. Olink Explore runs each block of proteins at its own dilution for this reason.
Matrix effects and cross-reactivity in multiplex panels
Section titled “Matrix effects and cross-reactivity in multiplex panels”Heterophile antibodies are the classic matrix effect. They can bridge the capture and detection antibodies with no analyte present, which gives a false positive, or block one of them, which gives a false negative, as Tighe et al. 2015 and Tate and Ward 2004 describe.
Multiplexing adds its own risk. In a bead assay every detection antibody meets every analyte and every other antibody in the well, and Tighe et al. 2015 report that the chance of an antibody binding the wrong target grows quadratically with the number of targets. A pair that works alone can misbehave in a panel. PEA reduces the problem by requiring both antibodies on one molecule, as the Affinity platforms page describes.
Reagent lots and batch effects
Section titled “Reagent lots and batch effects”A new kit lot can move every result. Feng et al. 2019 describe a two year plasma biomarker project in which control concentrations for one biomarker dropped significantly after a change of ELISA kit lot, because the standard curves of the new kits had shifted. Their fix became ELISAtools, which fits a reference curve and a shift factor for the standard curve of every plate.
M10 treats antibodies and other binding reagents as critical reagents, asks for their lot numbers on record, and asks that variability between lots be addressed when a study uses more than one kit lot. Buy one lot for all plates where you can. Where you cannot, record the lot on every plate and keep a common control running across the change.
What the analysis can correct later
Section titled “What the analysis can correct later”| Problem | What the design must provide | What the analysis can then do | What no analysis can do |
|---|---|---|---|
| Plate effect | groups randomized across plates | center each assay on each plate, as Olink intensity normalization does | separate plate from group when the two coincide |
| Shift between projects or kit lots | bridge samples, or a common control on every plate | bridge normalization, or a shift factor for each standard curve | bridge two runs that share no samples |
| Values outside the curve | standards and dilutions chosen for the expected range | flag values below the LLOQ or above the ULOQ, and use methods for censored data | recover a value below the LLOQ |
| Hook effect | a dilution series for high samples | detect it and keep the diluted result | rescue an undiluted well that hooked |
| Handling drift | handling recorded for every sample | adjust for handling, or exclude affected samples | undo protein released after the draw |
| Matrix differs between groups | one matrix and one tube type for every sample | nothing | separate the matrix from the group |
Next steps
Section titled “Next steps”The next page, The ELISA standard curve, fits four and five parameter curves to real plates and reads the samples off them.
Further reading
Section titled “Further reading”The Olink plate randomizer tutorial explains how sample attributes and allocation constraints enter a plate design. It gives a concrete implementation of the balance discussed here.
The Olink bridge normalization tutorial explains which shared samples connect projects and how the reference project determines adjustment direction. Read it before allocating bridge samples.