Skip to content

Proteomics

Proteomics measures the proteins themselves rather than the transcripts that code for them. This section starts with ELISA, Luminex and Olink, three affinity assays that many wet labs run before they turn to mass spectrometry. Each one uses antibodies to recognize proteins you chose in advance, and each one hands you a file that still needs work. A plate reader export holds optical densities. An xPONENT export holds bead counts and fluorescence. An Olink delivery holds NPX values with a limit of detection for every assay. These pages turn those files into concentrations or NPX values, check their quality, and compare groups.

No nf-core pipeline exists for these assays. The instrument software already turns the raw signal into an export, so the work starts from that file. Every output and figure on the gated pages comes from a real run of the code you can read on the page, in one pinned container, and no number reaches a page by hand.

The mass spectrometry route follows six DDA raw files from PXD002057 through quantms and into peptide and protein evidence. Its measurements, missing values, and identification errors require a separate analysis from the affinity assays. SomaScan remains outside the executed examples.

What protein measurement adds over RNA, how the platforms turn binding into a number, and the design choices that decide what the analysis can fix later.

Page What it does
What is proteomics affinity assays and mass spectrometry, the units each reports, and the dynamic range of plasma
Affinity platforms compared ELISA, Luminex xMAP, Olink PEA and SomaScan, side by side
Experimental design plates, standards, controls, bridging samples and sample handling, settled before the first plate

The DDA example compares three resistant SKBR3-AZDRc cultures with three parental SKBR3 cultures. The original deposited assay records establish the six condition assignments. The analysis retains the distinction between spectra, peptides, protein groups, and individual protein accessions.

Page Question
Measurement and acquisition What does DDA measure, and where does DIA require a different workflow?
Experimental design Which cultures supply independent observations for this contrast?
Dataset and inputs Do source identities, conditions, and files agree?
Primary workflow How do spectra become peptide and protein quantities?
Identification confidence Which error rate belongs to each identification level?
Quality and normalization Do run quality and quantity distributions support comparison?
Missing values Which protein groups have enough observed cultures for inference?
Differential abundance What relative protein effects does the defined contrast estimate?
Figures How do individual culture measurements support an estimated effect?
Pathway interpretation How do protein mapping and the tested universe constrain pathway claims?

The execution record supplies the raw input checks, fixed process images, and primary acceptance evidence. These pages use public PXD002057 inputs and preserve the source study’s interpretation limits.

One protein per well, read as an optical density and converted to a concentration through a standard curve on the same plate.

Page What it does
The ELISA standard curve four and five parameter logistic fits, and back calculated concentrations
Limits, replicates & plates LOD, LLOQ and ULOQ, replicate CVs, and the shift between batches of plates

Many proteins per well on colored beads, read as fluorescence, with one curve per analyte.

Page What it does
Bead counts & MFI QC bead counts, median fluorescence, and the wells to distrust, on a plate with known truth
Multiplex curves & censored values a five parameter curve for each analyte, and what values below the limit do to a group comparison

Relative protein levels on the log2 NPX scale, for hundreds to thousands of proteins at once.

Page What it does
NPX & QC the NPX table, values below LOD, and samples that stand apart
Bridging plates & projects bridge normalization between two projects with OlinkAnalyze, in R only
Differential abundance a model for each protein, and false discovery control across the panel
Visualization & pathways volcano plots, heatmaps, and pathway analysis of the proteins that change

Four public sources feed the pages, and one more input is synthetic.

Assay Data License Used on
ELISA the example plates of ELISAtools 0.1.8, SoftMax Pro exports read in more than one batch MIT both ELISA pages
Luminex a synthetic xPONENT plate written by generate_luminex_plate.R with a fixed seed generated both Luminex pages
Luminex Zenodo record 11160978, plasma cytokines of severe COVID-19 patients treated with or without dexamethasone CC0 1.0 Multiplex curves & censored values
Olink Mendeley Data 10.17632/nf853r8xsj.2, Olink Explore NPX values and clinical metadata of the MGH COVID-19 cohort CC BY 4.0 NPX & QC, Differential abundance, Visualization
Olink the example data of OlinkAnalyze 5.1.0 AGPL 3 or later, the license of the package Bridging

The ELISA plates are real optical densities, with a dilution series of standards on every plate. ELISAtools was written to correct the shift in standard curves between ELISA kit lots, a problem Feng et al. 2019 describe from a long plasma biomarker project. Its example plates come in more than one batch, which is what the plates page compares.

The Luminex QC and curve pages use a synthetic plate with known true values, because no open raw Luminex export with standards was found. A real export records bead counts and MFI but never the true concentration behind a well. The synthetic plate records both, so those pages can show how far a fitted curve lands from the truth. Each page that uses it says so at the top and names the generator script in the companion repository.

The Zenodo record comes from Neyton et al. 2024. The authors read their multiplex panel on a MAGPIX, analyzed it in xPONENT, and measured some analytes by singleplex ELISA instead. They report concentrations, not MFI, and they replaced values below the lower limit of the standard curve with a fixed fraction of that limit. No analysis can recover the original values, so the curves page shows how that choice moves a group comparison.

The MGH cohort is the plasma proteomics study of Filbin et al. 2021, with patients enrolled in the emergency department of a Boston hospital and EDTA plasma run on Olink Explore. The public workbook gives NPX values and one LOD for each assay, but no plate IDs and no QC flags, and the NPX page states what that leaves out. The OlinkAnalyze documentation calls both of its example NPX datasets synthetic. They share a set of bridge samples, which is what the bridging page needs.

The image downloads the public files at build time and checks each file against a SHA-256 value, and the pages run with the network disabled.

The gated pages run R and Python in synced tabs, so the language you pick on one page stays picked on the next. The R tabs fit curves with drc, handle ELISA batches with ELISAtools, read Olink data with OlinkAnalyze, and test proteins with limma. The Python tabs use SciPy, pandas and statsmodels.

Where the two languages compute the same value, such as a fitted curve parameter, a back calculated concentration or a test statistic, the gate checks that they agree through the parity file each page writes. drc and SciPy use different optimizers, so the tolerance for fitted parameters is relative rather than exact.

The bridging page is the exception and runs in R only. Bridge normalization lives in OlinkAnalyze, an R package from Olink, and that page says so.

The file layouts are on the Luminex and Olink NPX format pages. Start the Luminex curve lesson at plate calibration if you have MFI and standards. Start at reported concentrations if calibration and censoring have already happened.

The companion repository is private. Its proteomics image instructions and ELISA curve runner require repository access. Follow the tools, fixture and final image steps, then run bash guides/proteomics/elisa-standard-curve/run.sh from the repository root. It reads the packaged ELISA plate and writes fitted results and figures under guides/proteomics/elisa-standard-curve/outputs/. The /opt/data/ paths in the lessons refer to the image. The source links in the dataset table above provide the public data separately.