Skip to content

Design a mass spectrometry comparison

The biological sample determines the replication of a proteomics experiment. An additional injection can improve measurement precision, but it does not create another independent culture. Fractions divide a sample’s peptide mixture; they do not multiply its biological sample count.

Our example uses all six raw files in PXD002057. The study methods describe three biological replicates of parental SKBR3 and three of the resistant SKBR3-AZDRc derivative. Each selected raw file represents one run, with no separate fractions in this cohort.

Raw sample stem Cell line Biological replicate
130327_o2_01_hu_C1_2hr Resistant SKBR3-AZDRc 1
130327_o2_02_hu_P1_2hr Parental SKBR3 1
130327_o2_03_hu_C2_2hr Resistant SKBR3-AZDRc 2
130327_o2_04_hu_P2_2hr Parental SKBR3 2
130327_o2_05_hu_C3_2hr Resistant SKBR3-AZDRc 3
130327_o2_06_hu_P3_2hr Parental SKBR3 3

These assignments come from the experiment titles in the deposited PRIDE XML files, not from an interpretation of the C/P initials. The archive’s README also connects each XML file to its raw file. The overview checks these joins before any model uses a condition label.

The replicate numbers do not establish matched pairs across conditions. We use an unpaired condition model with parental as the reference. A positive coefficient means higher relative abundance in the resistant derivative.

All three resistant cultures come from one derivative. They are not three independently evolved resistant cell lines. The comparison can identify abundance differences between these cultured lines, but it cannot isolate every consequence of drug resistance from other differences acquired during derivation.

A wider claim would need additional resistant derivatives, appropriate controls, and a design that represents that wider population. Patient effects require patient samples. Neither a large number of peptides nor a large number of identified proteins changes the number of biological replicates.

The published experiment also used other cell lines and assays. Those measurements do not enter this six-file mass spectrometry model unless their sample identities and measurement process support the same analysis.

Control Question it can address Evidence in this cohort
Parental cultures How does the resistant derivative differ from the comparator? Three parental cultures supply the biological comparison.
Preparation blank Which signals can arise from reagents or handling? The selected archive has no separate blank run.
Pooled QC Does a repeated reference reveal acquisition drift? The selected archive has no pooled QC series.
Known spike-in Does the measurement recover a declared amount or ratio? The selected archive has no declared spike-in control.
Target-decoy search What identification error rate does the search estimate? The reanalysis generates decoys from the declared search database.

A target-decoy search cannot replace a blank, and a contaminant flag cannot reconstruct one. Run-level intensity and mass-error checks can expose problems, but the absence of a separate QC series limits what we can say about instrument drift.

Quality review uses complete run outputs, identification yield, mass error, intensity distributions, missingness, and sample correlations. A PCA plot is one part of that review. Separation by condition can reflect the biological comparison; an isolated point can reflect biology or a technical problem.

We require a specific technical reason before excluding a culture. The record must identify the evidence, the affected sample, and the resulting design. Removing a sample because it weakens a desired result would change the question after seeing the answer.

The main abundance filter requires measurements in at least two cultures per condition and two group-unique peptides. It selects measurable protein groups before significance tests. Groups observed in only one condition remain useful descriptive results, but we do not manufacture continuous abundance p-values by filling every missing measurement with a small number.

Continue with the sample and source checks before the primary workflow.

Creedon et al., 2016 describe the parental and resistant cell cultures, biological triplicates and original mass spectrometry analysis. The teaching reanalysis uses a different software workflow.

Creedon and colleagues, 2016, describe the resistant and parental cell cultures and the biological triplicates. Their methods establish what the six culture labels represent.

The PXD002057 archive record preserves the deposited experiment description. Compare it with the source study and the retained raw filenames when assigning the experimental unit.