DNA-seq reads the sequence of a genome, and the analysis looks for the positions where that sequence differs from a reference. RNA-seq counts molecules, so the number of reads on a gene is the measurement. In DNA-seq the count matters less than what the reads say.

A person carries two copies of each autosome, one from each parent. At a heterozygous site about half the reads carry the reference allele and half carry the alternative. At a homozygous alternative site nearly every read carries the alternative. Sequencing errors, misplaced reads and extra copies of a region that the reference lacks all produce patterns between those two expectations, and a variant caller has to tell them apart from real genotypes.

The chemistry is the Illumina sequencing by synthesis that What is RNA-seq describes, with genomic DNA in place of cDNA. The DNA is sheared into fragments of a few hundred bases, adapters are ligated to both ends, and each fragment is read from both ends. The files then follow one path.

FASTQ BAM or CRAM VCF
raw reads ───────► reads placed on ───────► the positions where
align the reference call the sample differs

The FASTQ, SAM and BAM and VCF pages describe each format. This section is about the two arrows.

Variants are grouped by size, because size decides what evidence a short read can carry.

Type Size What changes Evidence in short reads
SNV one base one base replaced by another the same mismatch in many reads at one position
Indel fewer than 50 bases bases inserted or deleted gaps in the alignment, or soft clips when the indel sits near a read end
Structural variant 50 bases or more deletions, insertions, inversions, duplications, translocations reads split across a breakpoint, pairs that land too far apart or in the wrong orientation, changes in depth
Copy number variant kilobases to megabases the number of copies of a segment a change in depth across the segment

The 50 base boundary between an indel and a structural variant is a convention, and the GIAB structural variant benchmark for HG002 uses it.

An SNV is the easiest call. A 150 base read contains the whole event, and the caller only decides whether a mismatch seen in many reads is a real allele or a repeated error. Indels are harder, because the aligner must open a gap, and a read that ends inside or close to an indel often aligns with a run of mismatches instead. GATK HaplotypeCaller reassembles the reads in every region that shows signs of variation, and its documentation gives this as the reason it calls indels much better than callers that look at one position at a time.

Structural variants are often longer than a read, so no single read contains one, and callers infer them from the evidence in the last column of the table. Copy number variants change the number of copies of a segment, and depth is their main signal. Sarek runs Manta and TIDDIT for structural variants and CNVkit for copy number, but this section calls SNVs and indels only.

Germline variants are inherited or arise in the germ line, so every cell of the body carries them. In a diploid genome their allele fractions cluster near 0.5 for a heterozygous site and near 1.0 for a homozygous one, and germline callers build that expectation into their genotype model. Somatic variants arise after conception in a subset of cells, a tumor being the usual case, and their allele fraction depends on the purity of the sample and on how many tumor cells carry them. It can be a few percent.

The two need different callers. The HaplotypeCaller documentation says its likelihood model is not suited to extreme allele frequencies and sends cancer work to Mutect2, and somatic callers usually compare the tumor with a matched normal sample to subtract the germline variants. Sarek runs both kinds, and its usage page lists which callers support germline, tumor only and tumor with normal data. This section is germline only.

Whole genome sequencing reads everything. Exome sequencing captures the exons with hybridization probes first, and the exome is about 1.5 percent of the human genome. A targeted panel captures or amplifies a chosen set of genes. The choice fixes what you can see.

Whole genome Whole exome Targeted panel
Target the whole genome the protein-coding exons a chosen list of genes or hotspots
Coverage evenness the most even depends on capture efficiency depends on probe or primer design
Noncoding variants called missed, apart from stray reads near the probes missed
Structural variants and CNVs from depth, pairs and split reads harder, since breakpoints often fall outside the targets limited to the targets
Data per sample the most less the least
Typical use rare disease, population studies coding variants in large cohorts known disease genes

Capture also costs accuracy inside the targets. When Belkadi et al. 2015 sequenced six people both ways, depth, genotype quality and minor read ratio were all more uniform for WGS. WGS also found a mean of 656 real coding SNVs per person that exome sequencing missed, about 3 percent of the coding SNVs that passed their quality filters.

Sarek runs all three designs. For an exome or a panel you pass the target BED with --intervals and set --wes, which changes the settings of several tools, DeepVariant’s model among them. This section’s reads are WGS, and --intervals only restricts the work to one region of chr20.

A short read is about 150 bases, and a pair spans a fragment of a few hundred. When a stretch of sequence longer than that exists in two or more nearly identical copies, the aligner cannot tell which copy a read came from. It places the read at one of them and gives it a mapping quality of 0, the value the SAM and BAM page describes for a read that maps equally well to several places. Callers drop such reads or weigh them down. The region then looks thin, and the bases that tell the copies apart turn into false variants or disappear.

Segmental duplications are the clearest case. Bailey et al. 2002 found about 5 percent of the human genome in duplications of at least 1 kb that share 90 percent identity or more, and clinically relevant genes sit inside them. The GIAB v4.2.1 benchmark added variants in medically relevant genes that the previous version had not covered, and Wagner et al. 2022 name the mismatch repair gene PMS2 as one.

Tandem repeats and long homopolymers fail in a different way. The read lands in the right place, but the polymerase slips while it copies the repeat, and the read reports an indel that is not in the genome. The Experimental design page covers the library choice that reduces these errors.

The truth set shows where the limits fall. GIAB built v4.2.1 with 10x Genomics linked reads and PacBio HiFi long reads as well as short reads, which took the benchmark into segmental duplications and other difficult regions and raised its coverage from 85 to 92 percent of the autosomal GRCh38 assembly. The rest stays out because it is problematic for benchmarking small variants, and regions with copy number variants are one example the authors give. Long reads of tens of kilobases span repeats that no short read can, and the long-read files page covers their formats.

This section adds an artificial version of the same problem. The reference is chr20 alone, so a read from similar sequence on another chromosome has no better place to go and aligns to chr20. The Benchmarking page explains what that does to the calls.

The next page, Experimental design, covers the choices that decide how much of the genome you can call before a single read exists.

The Sarek workflow guide shows how sequencing inputs become germline or somatic variant calls. It connects the broad assay types to a concrete analysis pipeline.